Abstract
Current clinical data suggest a higher failure rate for internal fixation in Vancouver type B1 periprosthetic femoral fracture (PFF) fixations compared to long stem revision in B2 fractures. The aim of this study was to compare the biomechanical performance of several fixations in the aforementioned fractures. Finite element models of B1 and B2 fixations, previously corroborated against in vitro experimental models, were compared. The results indicated that in treatment of B1 fractures, a single locking plate can be without complications provided partial weight bearing is followed. In case of B2 fractures, long stem revision and bypassing the fracture gap by two femoral diameters are recommended. Considering the risk of single plate failure, long stem revision could be considered in all comminuted B1 and B2 fractures.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2014 Elsevier Inc. All rights reserved. Uploaded in accordance with the publisher's self-archiving policy. NOTICE: this is the author’s version of a work that was accepted for publication in The Journal of Arthroplasty. Changes resulting from the publishing process, such as peer review, editing, corrections, structural formatting, and other quality control mechanisms may not be reflected in this document. Changes may have been made to this work since it was submitted for publication. A definitive version was subsequently published in The Journal of Arthroplasty, 29, 3,(2014) DOI 10.1016/j.arth.2013.08.010 |
Keywords: | Vancouver type B; Fracture; Strain; Stiffness; Finite element method |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Mechanical Engineering (Leeds) > Institute of Medical and Biological Engineering (iMBE) (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 16 Oct 2014 14:31 |
Last Modified: | 16 Oct 2014 14:31 |
Published Version: | http://dx.doi.org/10.1016/j.arth.2013.08.010 |
Status: | Published |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.arth.2013.08.010 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:80241 |