Abdelgaied, A orcid.org/0000-0003-0066-1688, Fisher, J orcid.org/0000-0003-3833-3700
and Jennings, LM orcid.org/0000-0003-1446-4511
(2018)
A Comprehensive Combined Experimental and Computational Framework for Pre-clinical Wear Simulation of Total Knee Replacements.
Journal of the Mechanical Behavior of Biomedical Materials, 78.
pp. 282-291.
ISSN 1751-6161
Abstract
A more robust pre-clinical wear simulation framework is required in order to simulate wider and higher ranges of activities, observed in different patient populations such as younger more active patients. Such a framework will help to understand and address the reported higher failure rates for younger and more active patients (National_Joint_Registry, 2016). The current study has developed and validated a comprehensive combined experimental and computational framework for pre-clinical wear simulation of total knee replacements (TKR). The input mechanical (elastic modulus and Poisson’s ratio) and wear parameters and of the moderately cross-linked ultra-high molecular weight polyethylene (UHMWPE) bearing material were independently measured from experimental studies under realistic test conditions, similar to the loading conditions found in the total knee replacements.. The wear predictions from the computational wear simulation were validated against the direct experimental wear measurements for size 3 Sigma curved total knee replacements (DePuy, UK) in an independent experimental wear simulation study under three different daily activities; walking, deep squat, and stairs ascending kinematic conditions. The measured compressive mechanical properties of the moderately cross-linked UHMWPE material were more than 20% lower than that reported in the literature under tensile test conditions. The pin-on-plate wear coefficient of moderately cross-linked UHMWPE was significantly dependant of the contact stress and the degree of cross-shear at the articulating surfaces. The computational wear predictions for the TKR from the current framework were consistent and in a good agreement with the independent full TKR experimental wear simulation measurements, with 0.94 coefficient of determination of the framework. In addition, the comprehensive combined experimental and computational framework was able to explain the complex experimental wear trends from the three different daily activities investigated. Therefore, such a framework can be adopted as a pre-clinical simulation approach to optimise different designs, materials, as well as patient’s specific total knee replacements for a range of activities.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2017 Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/BY/4.0/). |
Keywords: | Wear; moderately cross-linked ultra-high molecular weight polyethylene; total knee replacements; standard kinematics; deep squat; stairs ascending. |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Mechanical Engineering (Leeds) > Institute of Medical and Biological Engineering (iMBE) (Leeds) |
Funding Information: | Funder Grant number EPSRC N/A (IKC) Wellcome Trust 088908/Z/09/Z EPSRC EP/K029592/1 NIHR National Inst Health Research N/A |
Depositing User: | Symplectic Publications |
Date Deposited: | 17 Nov 2017 09:51 |
Last Modified: | 16 Dec 2024 13:55 |
Status: | Published |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.jmbbm.2017.11.022 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:124189 |
Download
Filename: 1-s2.0-S1751616117305106-main.pdf
Licence: CC-BY 4.0