Maqbool, HF orcid.org/0000-0003-3193-4984, Husman, MAB, Awad, MI orcid.org/0000-0002-0367-0187 et al. (3 more authors) (2017) A Real-Time Gait Event Detection for Lower Limb Prosthesis Control and Evaluation. IEEE Transactions on Neural Systems and Rehabilitation Engineering, 25 (9). pp. 1500-1509. ISSN 1534-4320
Abstract
Lower extremity amputees suffer from mobility limitations which will result in a degradation of their quality of life. Wearable sensors are frequently used to assess spatio-temporal, kinematic and kinetic parameters providing the means to establish an interactive control of the amputee-prosthesis-environment system. Gait events and the gait phase detection of an amputee’s locomotion are vital for controlling lower limb prosthetic devices. The paper presents an approach to real-time gait event detection for lower limb amputees using a wireless gyroscope attached to the shank when performing level ground and ramp activities. The results were validated using both healthy and amputee subjects and showed that the time differences in identifying Initial Contact (IC) and Toe Off (TO) events were larger in a transfemoral amputee when compared to the control subjects and a transtibial amputee (TTA). Overall, the time difference latency lies within a range of ± 50 ms while the detection rate was 100% for all activities. Based on the validated results, the IC and TO events can be accurately detected using the proposed system in both control subjects and amputees when performing activities of daily living and can also be utilized in the clinical setup for rehabilitation and assessing the performance of lower limb prosthesis users.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | (c) 2016 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works. |
Keywords: | Transtibial amputee; Event detection; Gyroscope; Lower limb prosthesis; Transfemoral amputee |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Mechanical Engineering (Leeds) > Institute of Engineering Systems and Design (iESD) (Leeds) |
Funding Information: | Funder Grant number EPSRC EP/K020463/1 |
Depositing User: | Symplectic Publications |
Date Deposited: | 20 Dec 2016 12:20 |
Last Modified: | 18 Jan 2018 14:15 |
Published Version: | https://doi.org/10.1109/TNSRE.2016.2636367 |
Status: | Published |
Publisher: | Institute of Electrical and Electronics Engineers (IEEE) |
Identification Number: | 10.1109/TNSRE.2016.2636367 |