Items where authors include "Jennings, LM"
Article
Ali, M orcid.org/0000-0002-4022-7993, Al-Hajjar, M orcid.org/0000-0001-5008-6138, Fisher, J et al. (1 more author) (2023) Wear and deformation of metal-on-polyethylene hip bearings under edge loading conditions due to variations in component positioning. Biotribology, 33-34. 100238. ISSN 2352-5738
Abdelgaied, A orcid.org/0000-0003-0066-1688, Fisher, J and Jennings, LM orcid.org/0000-0003-1446-4511 (2022) Understanding the differences in wear testing method standards for total knee replacement. Journal of the Mechanical Behavior of Biomedical Materials, 132. 105258. ISSN 1751-6161
Vafaee, T orcid.org/0000-0002-0733-9803, Walker, F orcid.org/0000-0001-7600-0822, Thomas, D orcid.org/0000-0001-5584-9114 et al. (9 more authors) (2022) Repopulation of decellularised porcine pulmonary valves in the right ventricular outflow tract of sheep: role of macrophages. Journal of Tissue Engineering, 13. ISSN 2041-7314
Statham, P, Jones, E orcid.org/0000-0001-9365-2283, Jennings, LM orcid.org/0000-0003-1446-4511 et al. (1 more author) (2022) Reproducing the biomechanical environment of the chondrocyte for cartilage tissue engineering. Tissue Engineering Part B: Reviews, 28 (2). pp. 405-420. ISSN 1937-3368
Desai, A orcid.org/0000-0001-8611-9958, Ingham, E orcid.org/0000-0002-9757-3045, Berry, HE orcid.org/0000-0003-2426-1881 et al. (2 more authors) (2022) The effect of decellularisation on the real time mechanical fatigue of porcine aortic heart valve roots. PLOS ONE, 17 (4). e0265763. ISSN 1932-6203
Clark, ER, Helliwell, RJ, Bailey, MA orcid.org/0000-0001-5038-1970 et al. (7 more authors) (2022) Preservation of Smooth Muscle Cell Integrity and Function: A Target for Limiting Abdominal Aortic Aneurysm Expansion? Cells, 11 (6). 1043. ISSN 2073-4409
Cowie, RM orcid.org/0000-0003-3903-5916 and Jennings, LM orcid.org/0000-0003-1446-4511 (2021) Third body damage and wear in arthroplasty bearing materials: A review of laboratory methods. Biomaterials and Biosystems, 4. 100028. p. 100028. ISSN 2666-5344
Holland, JDR, Webster, G, Rooney, P et al. (3 more authors) (2021) Effects of Chemical and Radiation Sterilisation on the Biological and Biomechanical Properties of Decellularised Porcine Peripheral Nerves. Frontiers in Bioengineering and Biotechnology, 9. 660453. ISSN 2296-4185
Cowie, RM orcid.org/0000-0003-3903-5916, Bowland, P, Baji, D et al. (4 more authors) (2021) An experimental simulation model to assess wear of the porcine patellofemoral joint. PLoS One, 16 (4). e0250077. ISSN 1932-6203
Liu, A orcid.org/0000-0001-6524-1698, Sanderson, WJ orcid.org/0000-0003-0170-9911, Ingham, E orcid.org/0000-0002-9757-3045 et al. (2 more authors) (2020) Development of a specimen-specific in vitro pre-clinical simulation model of the human cadaveric knee with appropriate soft tissue constraints. PLoS One, 15 (10). e0238785. ISSN 1932-6203
Cooper, RJ orcid.org/0000-0001-5255-1486, Liu, A orcid.org/0000-0001-6524-1698, Day, GA orcid.org/0000-0003-2197-8318 et al. (4 more authors) (2020) Development of robust finite element models of porcine tibiofemoral joints loaded under varied flexion angles and tibial freedoms. Journal of the Mechanical Behavior of Biomedical Materials, 109. 103797. ISSN 1751-6161
de Ruiter, L, Cowie, RM orcid.org/0000-0003-3903-5916, Jennings, LM orcid.org/0000-0003-1446-4511 et al. (3 more authors) (2020) The Effects of Cyclic Loading and Motion on the Implant–Cement Interface and Cement Mantle of PEEK and Cobalt–Chromium Femoral Total Knee Arthroplasty Implants: A Preliminary Study. Materials, 13 (15). 3323. p. 3323. ISSN 1996-1944
Cowie, RM orcid.org/0000-0003-3903-5916, Pallem, NM, Briscoe, A et al. (1 more author) (2020) Third body wear of UHMWPE-on-PEEK-OPTIMA. Materials, 13 (6). 1264. ISSN 1996-1944
Bowland, P, Cowie, RM orcid.org/0000-0003-3903-5916, Ingham, E orcid.org/0000-0002-9757-3045 et al. (2 more authors) (2020) Biomechanical assessment of the stability of osteochondral grafts implanted in porcine and bovine femoral condyles. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 234 (2). pp. 163-170. ISSN 0954-4119
Johnston, H orcid.org/0000-0002-4086-2727, Abdelgaied, A, Pandit, H orcid.org/0000-0001-7392-8561 et al. (2 more authors) (2019) The effect of surgical alignment and soft tissue conditions on the kinematics and wear of a fixed bearing total knee replacement. Journal of the Mechanical Behavior of Biomedical Materials, 100. ARTN 103386. ISSN 1751-6161
Al-Hajjar, M orcid.org/0000-0001-5008-6138, Gremillard, L orcid.org/0000-0001-7258-6483, Begand, S et al. (5 more authors) (2019) Combined wear and ageing of ceramic-on-ceramic bearings in total hip replacement under edge loading conditions. Journal of the Mechanical Behavior of Biomedical Materials, 98. pp. 40-47. ISSN 1751-6161
Ali, M orcid.org/0000-0002-4022-7993, Al-Hajjar, M orcid.org/0000-0001-5008-6138, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2019) The Influence of Kinematic Conditions and Variations in Component Positioning on the Severity of Edge Loading and Wear of Ceramic-on-Ceramic Hip Bearings. Ceramics, 2 (3). pp. 488-501. ISSN 2571-6131
Liu, A orcid.org/0000-0001-6524-1698, Ingham, E orcid.org/0000-0002-9757-3045, Fisher, J et al. (1 more author) (2019) Development of a pre-clinical experimental simulation model of the natural porcine knee with appropriate ligamentous constraints. PLoS ONE, 14 (5). e0216872. ISSN 1932-6203
Cowie, RM orcid.org/0000-0003-3903-5916, Aiken, SS, Cooper, JJ et al. (1 more author) (2019) The influence of a calcium sulphate bone void filler on the third-body damage and polyethylene wear of total knee arthroplasty. Bone & Joint Research, 8 (2). pp. 65-72. ISSN 2046-3758
Cowie, RM orcid.org/0000-0003-3903-5916, Adam, B, Fisher, J et al. (1 more author) (2019) Wear and Friction of UHMWPE-on-PEEK OPTIMA™. Journal of the Mechanical Behavior of Biomedical Materials, 89. pp. 65-71. ISSN 1751-6161
Johnston, H orcid.org/0000-0002-4086-2727, Abdelgaied, A orcid.org/0000-0003-0066-1688, Pandit, H orcid.org/0000-0001-7392-8561 et al. (2 more authors) (2018) Representing the Effect of Variation in Soft Tissue Constraints in Experimental Simulation of Total Knee Replacements. Journal of the Mechanical Behavior of Biomedical Materials, 87. pp. 87-94. ISSN 1751-6161
Aldridge, A, Desai, A, Owston, H et al. (6 more authors) (2018) Development and characterisation of a large diameter decellularised vascular allograft. Cell and Tissue Banking, 19 (3). pp. 287-300. ISSN 1389-9333
Bowland, P, Ingham, E orcid.org/0000-0002-9757-3045, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2018) Development of a preclinical natural porcine knee simulation model for the tribological assessment of osteochondral grafts in vitro. Journal of Biomechanics, 77. pp. 91-98. ISSN 0021-9290
O'Dwyer Lancaster-Jones, O orcid.org/0000-0002-8434-7268, Williams, S orcid.org/0000-0002-6963-965X, Jennings, LM orcid.org/0000-0003-1446-4511 et al. (4 more authors) (2018) An in vitro simulation model to assess the severity of edge loading and wear, due to variations in component positioning in hip joint replacements. Journal of Biomedical Materials Research - Part B Applied Biomaterials, 106 (5). pp. 1897-1906. ISSN 1552-4973
Desai, A orcid.org/0000-0001-8611-9958, Vafaee, T orcid.org/0000-0002-0733-9803, Rooney, P orcid.org/0000-0003-3724-5717 et al. (5 more authors) (2018) In vitro biomechanical and hydrodynamic characterisation of decellularised human pulmonary and aortic roots. Journal of the Mechanical Behavior of Biomedical Materials, 79. pp. 53-63. ISSN 1751-6161
Bowland, P, Ingham, E orcid.org/0000-0002-9757-3045, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2018) Simple geometry tribological study of osteochondral graft implantation in the knee. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232 (3). pp. 249-256. ISSN 0954-4119
Brockett, CL orcid.org/0000-0002-6664-7259, Carbone, S, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2018) Influence of conformity on the wear of total knee replacement: An experimental study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 232 (2). pp. 127-134. ISSN 0954-4119
Abdelgaied, A orcid.org/0000-0003-0066-1688, Fisher, J orcid.org/0000-0003-3833-3700 and Jennings, LM orcid.org/0000-0003-1446-4511 (2018) A Comprehensive Combined Experimental and Computational Framework for Pre-clinical Wear Simulation of Total Knee Replacements. Journal of the Mechanical Behavior of Biomedical Materials, 78. pp. 282-291. ISSN 1751-6161
Vafaee, T orcid.org/0000-0002-0733-9803, Thomas, D orcid.org/0000-0001-5584-9114, Desai, A orcid.org/0000-0001-8611-9958 et al. (6 more authors) (2018) Decellularization of human donor aortic and pulmonary valved conduits using low concentration sodium dodecyl sulfate. Journal of Tissue Engineering and Regenerative Medicine, 12 (2). e841-e853. ISSN 1932-6254
Al-Hajjar, M orcid.org/0000-0001-5008-6138, Carbone, S, Jennings, LM orcid.org/0000-0003-1446-4511 et al. (4 more authors) (2017) Wear of composite ceramics in mixed-material combinations in total hip replacement under adverse edge loading conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 105 (6). pp. 1361-1368. ISSN 1552-4973
Abdelgaied, A orcid.org/0000-0003-0066-1688, Fisher, J orcid.org/0000-0003-3833-3700 and Jennings, LM orcid.org/0000-0003-1446-4511 (2017) A comparison between electromechanical and pneumatic-controlled knee simulators for the investigation of wear of total knee replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 231 (7). pp. 643-651. ISSN 0954-4119
Maiti, R, Cowie, RM orcid.org/0000-0003-3903-5916, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2017) The influence of malalignment and ageing following sterilisation by gamma irradiation in an inert atmosphere on the wear of ultra-high-molecular-weight polyethylene in patellofemoral replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 231 (7). pp. 634-642. ISSN 0954-4119
Brockett, CL orcid.org/0000-0002-6664-7259, Carbone, S, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2017) PEEK and CFR-PEEK as alternative bearing materials to UHMWPE in a fixed bearing total knee replacement: An experimental wear study. Wear, 374-37. pp. 86-91. ISSN 0043-1648
Cowie, RM orcid.org/0000-0003-3903-5916, Briscoe, A, Fisher, J orcid.org/0000-0003-3833-3700 et al. (1 more author) (2016) PEEK-OPTIMA as an alternative to cobalt chrome in the femoral component of total knee replacement: A preliminary study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230 (11). pp. 1008-1015. ISSN 0954-4119
Brockett, CL orcid.org/0000-0002-6664-7259, Carbone, S, Abdelgaied, A orcid.org/0000-0003-0066-1688 et al. (2 more authors) (2016) Influence of contact pressure, cross-shear and counterface material on the wear of PEEK and CFR-PEEK for orthopaedic applications. Journal of the Mechanical Behavior of Biomedical Materials, 63. pp. 10-16. ISSN 1751-6161
Cowie, RM orcid.org/0000-0003-3903-5916, Carbone, S, Aiken, S et al. (2 more authors) (2016) Influence of third-body particles originating from bone void fillers on the wear of ultra-high-molecular-weight polyethylene. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230 (8). pp. 775-783. ISSN 0954-4119
Brockett, C orcid.org/0000-0002-6664-7259, Abdelgaied, A, Haythornthwaite, T et al. (3 more authors) (2016) The influence of simulator input conditions on the wear of total knee replacements: An experimental and computational study. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230 (5). pp. 429-439. ISSN 0954-4119
Ali, M orcid.org/0000-0002-4022-7993, Al-Hajjar, M orcid.org/0000-0001-5008-6138, Partridge, S orcid.org/0000-0003-3509-1662 et al. (3 more authors) (2016) Influence of hip joint simulator design and mechanics on the wear and creep of metal-on-polyethylene bearings. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 230 (5). pp. 389-397. ISSN 0954-4119
Bowland, P, Ingham, E, Jennings, LM et al. (1 more author) (2015) Review of the biomechanics and biotribology of osteochondral grafts used for surgical interventions in the knee. Proceedings of the Institution of Mechanical Engineers, 229 (12). 879 - 888. ISSN 0954-4119
Liu, A, Jennings, LM, Ingham, E et al. (1 more author) (2015) Tribology studies of the natural knee using an animal model in a new whole joint natural knee simulator. Journal of Biomechanics, 48 (12). 3004 - 3011. ISSN 0021-9290
Luo, J, Korossis, SA, Wilshaw, SP et al. (3 more authors) (2014) Development and characterization of acellular porcine pulmonary valve scaffolds for tissue engineering. Tissue engineering. Part A. ISSN 1937-3341
Maiti, R, Fisher, J, Rowley, LR et al. (1 more author) (2014) The influence of kinematic conditions and design on the wear of patella-femoral replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 228 (2). 175 - 181. ISSN 0954-4119
Abdelgaied, A, Brockett, CL, Liu, F et al. (3 more authors) (2014) The effect of insert conformity and material on total knee replacement wear. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 228 (1). 98 - 106. ISSN 0954-4119
Al-Hajjar, M, Jennings, LM, Begand, S et al. (3 more authors) (2013) Wear of novel ceramic-on-ceramic bearings under adverse and clinically relevant hip simulator conditions. Journal of Biomedical Materials Research Part B: Applied Biomaterials, 101 (8). 1456 - 1462. ISSN 0021-9304
Al-Hajjar, M, Fisher, J, Tipper, JL et al. (2 more authors) (2013) Wear of 36-mm BIOLOX(R) delta ceramic-on-ceramic bearing in total hip replacements under edge loading conditions. Proceedings of the Institution of Mechanical Engineers Part H: Journal of Engineering in Medicine, 227 (5). 535 - 542. ISSN 0954-4119
Al-Hajjar, M orcid.org/0000-0001-5008-6138, Fisher, J orcid.org/0000-0003-3833-3700, Williams, S orcid.org/0000-0002-6963-965X et al. (2 more authors) (2013) Effect of femoral head size on the wear of metal on metal bearings in total hip replacements under adverse edge‐loading conditions. Journal of Biomedical Materials Research. Part B: Applied Biomaterials, 101B (2). pp. 213-222. ISSN 1552-4973
Abdelgaied, A, Brockett, CL, Liu, F et al. (3 more authors) (2013) Quantification of the effect of cross-shear and applied nominal contact pressure on the wear of moderately cross-linked polyethylene. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 227 (1). 18 - 26. ISSN 0954-4119
Jennings, LM, Al-Hajjar, M, Brockett, CL et al. (4 more authors) (2012) (iv) Enhancing the safety and reliability of joint replacement implants. Orthopaedics and Trauma, 26 (4). 246 - 252. ISSN 1877-1327
Brockett, CL orcid.org/0000-0002-6664-7259, Jennings, LM orcid.org/0000-0003-1446-4511, Hardaker, C et al. (1 more author) (2012) Wear of moderately cross-linked polyethylene in fixed-bearing total knee replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 226 (7). pp. 529-535. ISSN 0954-4119
Brockett, CL orcid.org/0000-0002-6664-7259, Jennings, LM and Fisher, J (2012) Wear of knee prostheses. Orthopedic Research and Reviews, 4. pp. 19-26. ISSN 1179-1462
Brockett, CL orcid.org/0000-0002-6664-7259, Jennings, LM orcid.org/0000-0003-1446-4511 and Fisher, J orcid.org/0000-0003-3833-3700 (2011) The wear of fixed and mobile bearing unicompartmental knee replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 225 (H5). pp. 511-519. ISSN 0954-4119
Book Section
Ali, M, Al-Hajjar, M orcid.org/0000-0001-5008-6138 and Jennings, LM orcid.org/0000-0003-1446-4511 (2015) Tribology of UHMWPE in the Hip. In: UHMWPE Biomaterials Handbook. Elsevier , pp. 579-595. ISBN 9780323354011
Conference or Workshop Item
Aslam, S, Desai, A, Rooney, P et al. (3 more authors) (2022) THE IMPACT OF SUPERCRITICAL CARBON DIOXIDE ON THE BIOLOGICAL AND BIOMECHANICAL PROPERTIES OF DECELLULARISED HEART VALVES. In: TERMIS 2021, 15-19 Nov 2021, Online.