Zhang, Yilong, Feng, Zhengshuyi, Huang, Zhihong orcid.org/0000-0001-7399-0250 et al. (1 more author) (2024) Characterizing Viscoelasticity of Corneal Stromal Models Using Non-Contact Air-Pulse Optical Coherence Elastography (OCE) and Validating Using Ramp–Hold Relaxation Testing. Photonics. 24. ISSN: 2304-6732
Abstract
Corneal biomechanical properties are closely related to the cornea’s physiological and pathological conditions, primarily determined by the stromal layer. However, little is known about the influence of corneal cell interaction on the viscoelasticity of the stromal extracellular matrix (ECM). In this study, collagen-based hydrogels incorporated with keratocytes were reconstructed as corneal stromal models. Air-pulse optical coherence elastography (OCE) was used to characterize the viscoelastic properties of the corneal models. Plate compression, ramp–hold relaxation testing was performed on the initial corneal models. The findings demonstrated that the elastic modulus increased 5.27, 2.65 and 1.42 kPa, and viscosity increased 0.22, 0.06 and 0.09 Pa·s in the stromal models with initial collagen concentrations of 3, 5, and 7 mg/mL over 7 days. The elastic modulus and viscosity exhibited high correlation coefficients between air-pulse OCE and ramp–hold relaxation testing, with 92.25% and 98.67%, respectively. This study enhances the understanding of the influence of cell–matrix interactions on the corneal viscoelastic properties and validates air-pulse OCE as an accurate method for the mechanical characterization of tissue-engineered materials.
Metadata
| Item Type: | Article |
|---|---|
| Authors/Creators: |
|
| Copyright, Publisher and Additional Information: | Publisher Copyright: © 2024 by the authors. |
| Keywords: | air-pulse optical coherence elastography,collagen-based hydrogels,corneal stromal model,ramp–hold relaxation testing,surface acoustic wave,viscoelasticity |
| Dates: |
|
| Institution: | The University of York |
| Academic Units: | The University of York > Faculty of Sciences (York) > Electronic Engineering (York) |
| Date Deposited: | 04 Feb 2026 16:00 |
| Last Modified: | 04 Feb 2026 16:00 |
| Published Version: | https://doi.org/10.3390/photonics12010024 |
| Status: | Published |
| Refereed: | Yes |
| Identification Number: | 10.3390/photonics12010024 |
| Related URLs: | |
| Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:237554 |
Download
Filename: photonics-12-00024.pdf
Description: Characterizing Viscoelasticity of Corneal Stromal Models Using Non-Contact Air-Pulse Optical Coherence Elastography (OCE) and Validating Using Ramp–Hold Relaxation Testing
Licence: CC-BY 2.5

CORE (COnnecting REpositories)
CORE (COnnecting REpositories)