Shamas, J. orcid.org/0000-0001-5596-1296, Krynkin, A. orcid.org/0000-0002-8495-691X, Sailor, G. et al. (3 more authors) (2024) Fibre-optic sensing for analysis of turbulent pressure fluctuations in partially filled pipes. In: Acoustics 2024. Acoustics 2024, 12-13 Sep 2024, Manchester, United Kingdom. Institute of Acoustics. ISBN: 9781906913496. ISSN: 1478-6095.
Abstract
The authors present experimental data obtained from the turbulence-induced vibration of a fibre-optic sensor structure flush-mounting the interior of a partially-filled pipe rig. Methodology capable of estimating the free stream velocity and spatial correlations of the turbulent pressure fluctuations within the boundary layer is presented. The proposed methodology is validated through application to fibre-optic cable data from multiple flow regimes, as well LES-obtained near-wall pressure fluctuation data for the equivalent flow regimes.
Metadata
| Item Type: | Proceedings Paper |
|---|---|
| Authors/Creators: |
|
| Copyright, Publisher and Additional Information: | © Institute of Acoustics 2024 |
| Dates: |
|
| Institution: | The University of Sheffield |
| Academic Units: | The University of Sheffield > Faculty of Engineering (Sheffield) > School of Mechanical, Aerospace and Civil Engineering The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield) |
| Date Deposited: | 13 Feb 2026 15:31 |
| Last Modified: | 13 Feb 2026 15:32 |
| Published Version: | https://web.archive.org/web/20250505093222/https:/... |
| Status: | Published |
| Publisher: | Institute of Acoustics |
| Refereed: | Yes |
| Identification Number: | 10.25144/23667 |
| Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:236753 |