Azizi, S orcid.org/0000-0002-9274-1177, Sun, M, Liu, G et al. (2 more authors) (2020) High-Speed Distance Relaying of the Entire Length of Transmission Lines without Signaling. IEEE Transactions on Power Delivery, 35 (4). pp. 1949-1959. ISSN 0885-8977
Abstract
Short-circuit faults close to either end of a transmission line, are normally cleared instantaneously by the distance relay at that end and after hundreds of milliseconds, i.e., in Zone 2 operating time, by the relay at the opposite end of the line. This sequential tripping can be accelerated on condition that a reliable communication link is available for signaling between the two line ends. This paper proposes a novel non-communication method providing high-speed distance relaying over the entire length of the protected transmission line. The inputs to the method are the protected line parameters and local voltage and current signals measured by the relay, similar to those to conventional distance relays. The proposed method accomplishes Accelerated Sequential Tripping (AST) within a couple of cycles after the opening of the remote-end circuit breaker (ORCB) of the line. To achieve this, an accurate closed-form solution is derived for the fault distance in terms of post-ORCB voltage and current phasors. For the detection of the ORCB instant, a set of proper indices are proposed. This is to verify the fault distance calculated by the relay, before issuing a trip command. The proposed method is successfully validated by conducting more than 20000 hardware-in-the-loop (HIL) tests, and also using real-life data.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | This paper is protected by copyright. Personal use of this material is permitted. Permission from IEEE must be obtained for all other uses, in any current or future media, including reprinting/republishing this material for advertising or promotional purposes, creating new collective works, for resale or redistribution to servers or lists, or reuse of any copyrighted component of this work in other works. |
Keywords: | Accelerated sequential tripping (AST), Distance relays, Opening of the remote-end circuit breaker (ORCB), Realtime digital simulator (RTDS). |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Electronic & Electrical Engineering (Leeds) > Institute of Communication & Power Networks (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 04 Dec 2019 13:30 |
Last Modified: | 19 Aug 2020 15:26 |
Status: | Published |
Publisher: | IEEE |
Identification Number: | 10.1109/TPWRD.2019.2957302 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:154165 |