Maiti, R, Fisher, J, Rowley, LR et al. (1 more author) (2014) The influence of kinematic conditions and design on the wear of patella-femoral replacements. Proceedings of the Institution of Mechanical Engineers, Part H: Journal of Engineering in Medicine, 228 (2). 175 - 181. ISSN 0954-4119
Abstract
The success rate of patella-femoral arthroplasty varies between 44% and 90% in 17 years of follow-up. Several studies have been performed previously for assessing the surface wear in the patella-femoral joint. However, they have not included all six degrees of freedom. The aim of this study was to develop a six-axis patella-femoral joint simulator to assess the wear rate for two patellae designs (round and oval dome) at different kinematic conditions. An increase in patellar rotation from 1° to 4° led to a significantly (p<0.049) increased wear rate of round dome from 8.6 mm3/million cycles to 12.3 mm3/million cycles. The wear rate for oval dome increased from 6.3 mm3/million cycles to 14.5 mm3/million cycles. However, the increase was nonsignificant (p>0.08). The increase in wear rate was likely due to the higher cross shear. A decrease in patellar medial lateral displacement from passive to constrained resulted in a nonsignificant reduction in wear (p>0.06). There was no significant difference in wear rate between the two patellae designs (p>0.28). The volumetric wear under all conditions was positively correlated with the level of passive patellar tilt (rho>0.8). This is the first report of preclinical wear simulation of patella-femoral joint in a six-axis simulator under different kinematic conditions.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | This article is distributed under the terms of the Creative Commons Attribution 3.0 License (http://www.creativecommons.org/licenses/by/3.0/) which permits any use, reproduction and distribution of the work without further permission provided the original work is attributed as specified on the SAGE and Open Access page (http://www.uk.sagepub.com/aboutus/openaccess.htm). |
Keywords: | Knee replacement; patella-femoral joint; wear; arthroplasty; in vitro |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Mechanical Engineering (Leeds) > Institute of Medical and Biological Engineering (iMBE) (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 17 Feb 2014 11:40 |
Last Modified: | 23 Jun 2023 21:37 |
Published Version: | http://dx.doi.org/10.1177/0954411913518910 |
Status: | Published |
Publisher: | Sage |
Identification Number: | 10.1177/0954411913518910 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:77479 |