(2020) A compact fission detector for fission-tagging neutron capture experiments with radioactive fissile isotopes. Nuclear Instruments and Methods in Physics Research, Section A: Accelerators, Spectrometers, Detectors and Associated Equipment. 163981. ISSN 0168-9002
Abstract
In the measurement of neutron capture cross-sections of fissile isotopes, the fission channel is a source of background which can be removed efficiently using the so-called fission-tagging or fission-veto technique. For this purpose a new compact and fast fission chamber has been developed. The design criteria and technical description of the chamber are given within the context of a measurement of the 233U(n, γ) cross-section at the n_TOF facility at CERN, where it was coupled to the n_TOF Total Absorption Calorimeter. For this measurement the fission detector was optimized for time resolution, minimization of material in the neutron beam and for alpha-fission discrimination. The performance of the fission chamber and its application as a fission tagging detector are discussed.
Metadata
Item Type: | Article |
---|---|
Copyright, Publisher and Additional Information: | ©2020 The Authors |
Keywords: | U,Fission detector,n_TOF,Time-of-flight |
Dates: |
|
Institution: | The University of York |
Academic Units: | The University of York > Faculty of Sciences (York) > Physics (York) |
Depositing User: | Pure (York) |
Date Deposited: | 11 Sep 2020 09:50 |
Last Modified: | 17 Oct 2024 08:44 |
Published Version: | https://doi.org/10.1016/j.nima.2020.163981 |
Status: | Published |
Refereed: | Yes |
Identification Number: | 10.1016/j.nima.2020.163981 |
Related URLs: | |