Bai, L, Lin, G, Mu, Z et al. (1 more author) (2014) Theoretical analysis of steady-state performance of a loop heat pipe with a novel evaporator. Applied Thermal Engineering, 64 (1-2). pp. 233-241. ISSN 1359-4311
Abstract
A novel evaporator that features very small heat leak from the evaporator to the compensation chamber (CC) is proposed to improve the operating performance and reliability of loop heat pipes (LHPs). The mathematical model of the steady-state operation of the LHP is established, and its operating characteristics and heat transport limit are theoretically investigated. The modeling results show that the novel evaporator design can significantly reduce the heat leak from the evaporator to the CC. In this new evaporator design, the liquid flow pressure drop in the evaporator wick becomes the major component of the total pressure drop, and the LHP operation becomes insensitive to the adverse elevation. The heat transport limit of the LHP is found to be determined by the boiling limit under low adverse elevation, and by the capillary limit at relatively large adverse elevation.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Keywords: | Loop heat pipe; Mathematical model; Operating characteristics; Capillary limit; Boiling limit |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Chemical & Process Engineering (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 29 Jun 2016 10:06 |
Last Modified: | 03 Nov 2016 18:39 |
Published Version: | http://dx.doi.org/10.1016/j.applthermaleng.2013.12... |
Status: | Published |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.applthermaleng.2013.12.052 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:95746 |