Grimpampi, E., Oesen, S., Halper, B. et al. (3 more authors) (2015) Reliability of gait variability assessment in older individuals during a six-minute walk test. Journal of Biomechanics, 48 (15). pp. 4185-4189. ISSN 0021-9290
Abstract
Gait variability is an important indicator of gait performance. However, the reliability of the parameters used for its quantification, obtained from trunk linear accelerations, has still not been thoroughly investigated. The aim of this study is to assess the reliability of gait variability assessment in healthy older individuals based on lower trunk accelerations during a six-minute walk test and to examine the reliability of the data acquired in shorter periods. Twenty-nine subjects (84±5 years) performed the test while wearing one inertial sensor on the lower trunk. Gait variability parameters (standard deviation and coefficient of variation of the stride duration, and correlation coefficients of accelerations between neighbouring strides) were calculated from the accelerations over 35 rectilinear strides observed during six series of one-minute intervals extracted from the original signal. The reliability of these parameters was assessed using intraclass correlation coefficients (ICC). Results showed no significant changes across the six series for any of the parameters, with very high ICC values (0.93–0.95), indicating a strong reliability of the observed quantities. Therefore, gait variability analysis based on lower trunk acceleration data is a reliable and informative quantity in gait performance assessment in older individuals, and 1 min interval is sufficient to ensure reliable results.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2015 Elsevier. This is an author produced version of a paper subsequently published in Journal of Biomechanics. Uploaded in accordance with the publisher's self-archiving policy. Article available under the terms of the CC-BY-NC-ND licence (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
Keywords: | Gait variability; Reliability; Accelerometers; Six-minute walk test |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield) |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 02 Nov 2015 14:21 |
Last Modified: | 16 Jan 2017 19:22 |
Published Version: | http://dx.doi.org/10.1016/j.jbiomech.2015.10.008 |
Status: | Published |
Publisher: | Elsevier |
Refereed: | Yes |
Identification Number: | 10.1016/j.jbiomech.2015.10.008 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:91015 |