Bridgeman, J., Baker, A., Brown, D. et al. (1 more author) (2015) Portable LED fluorescence instrumentation for the rapid assessment of potable water quality. Science of the Total Environment, 524. 338 - 346. ISSN 0048-9697
Abstract
Characterising the organic and microbial matrix of water are key issues in ensuring a safe potable water supply. Current techniques only confirm water quality retrospectively via laboratory analysis of discrete samples. Whilst such analysis is required for regulatory purposes, it would be highly beneficial to monitor water quality in-situ in real time, enabling rapid water quality assessment and facilitating proactive management of water supply systems. A novel LED-based instrument, detecting fluorescence peaks C and T (surrogates for organic and microbial matter, respectively), was constructed and performance assessed. Results from over 200 samples taken from source waters through to customer tap from three UK water companies are presented. Excellent correlation was observed between the new device and a research grade spectrophotometer (r 2 = 0.98 and 0.77 for peak C and peak T respectively), demonstrating the potential of providing a low cost, portable alternative fluorimeter. The peak C/TOC correlation was very good (r 2 = 0.75) at low TOC levels found in drinking water. However, correlations between peak T and regulatory measures of microbial matter (2 day/3 day heterotrophic plate counts (HPC), E. coli, and total coliforms) were poor, due to the specific nature of these regulatory measures and the general measure of peak T. A more promising correlation was obtained between peak T and total bacteria using flow cytometry. Assessment of the fluorescence of four individual bacteria isolated from drinking water was also considered and excellent correlations found with peak T (Sphingobium sp. (r 2 = 0.83); Methylobacterium sp. (r 2 = 1.0); Rhodococcus sp. (r 2 = 0.86); Xenophilus sp. (r 2 = 0.96)). It is notable that each of the bacteria studied exhibited different levels of fluorescence as a function of their number. The scope for LED based instrumentation for insitu, real time assessment of the organic and microbial matrix of potable water is clearly demonstrated.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2015 The Author(s). This is an Open Access article distributed under the terms of the Creative Commons Attribution Licence (http://creativecommons.org/licenses/by/3.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
Keywords: | Fluorescence; LEDs; Organic matter; Microbial matter; Potable water quality |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Civil and Structural Engineering (Sheffield) |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 20 Aug 2015 17:10 |
Last Modified: | 20 Aug 2015 17:10 |
Published Version: | http://dx.doi.org/10.1016/j.scitotenv.2015.04.050 |
Status: | Published |
Publisher: | Elsevier |
Refereed: | Yes |
Identification Number: | 10.1016/j.scitotenv.2015.04.050 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:88627 |