Olerni, C, Jia, J and Wang, M (2013) Measurement of air distribution and void fraction of an upwards air-water flow using electrical resistance tomography and a wire-mesh sensor. Measurement Science and Technology, 24 (3). ARTN 035403. ISSN 0957-0233
Abstract
Measurements on an upwards air-water flow are reported that were obtained simultaneously with a dual-plane electrical resistance tomograph (ERT) and a wire-mesh sensor (WMS). The ultimate measurement target of both ERT and WMS is the same, the electrical conductivity of the medium. The ERT is a non-intrusive device whereas the WMS requires a net of wires that physically crosses the flow. This paper presents comparisons between the results obtained simultaneously from the ERT and the WMS for evaluation and calibration of the ERT. The length of the vertical testing pipeline section is 3 m with an internal diameter of 50 mm. Two distinct sets of air-water flow rate scenarios, bubble and slug regimes, were produced in the experiments. The fast impedance camera ERT recorded the data at an approximate time resolution of 896 frames per second (fps) per plane in contrast with the 1024 fps of the wire-mesh sensor WMS200. The set-up of the experiment was based on well established knowledge of air-water upwards flow, particularly the specific flow regimes and wall peak effects. The local air void fraction profiles and the overall air void fraction were produced from two systems to establish consistency for comparison of the data accuracy. Conventional bulk flow measurements in air mass and electromagnetic flow metering, as well as pressure and temperature, were employed, which brought the necessary calibration to the flow measurements. The results show that the profiles generated from the two systems have a certain level of inconsistency, particularly in a wall peak and a core peak from the ERT and WMS respectively, whereas the two tomography instruments achieve good agreement on the overall air void fraction for bubble flow. For slug flow, when the void fraction is over 30%, the ERT underestimates the void fraction, but a linear relation between ERT and WMS is still observed.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2013. IOP Publishing. This is an author produced version of a paper published in Measurement Science and Technology. Uploaded in accordance with the publisher's self-archiving policy. DOI10.1088/0957-0233/24/3/035403 |
Keywords: | electrical resistance tomography; local air void fraction profile; upwards air-water flow measurements; wire-mesh sensor |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Chemical & Process Engineering (Leeds) > Institute for Particle Science and Engineering (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 12 Dec 2014 11:22 |
Last Modified: | 11 May 2015 05:52 |
Published Version: | http://dx.doi.org/10.1088/0957-0233/24/3/035403 |
Status: | Published |
Publisher: | IOP Publishing |
Identification Number: | 10.1088/0957-0233/24/3/035403 |
Related URLs: | |