Giannoudis, V.P., Rodham, P. orcid.org/0000-0002-4094-4722, Antypas, A. et al. (3 more authors) (2023) Patient perspective on the use of carbon fibre plates for extremity fracture fixation. European Journal of Orthopaedic Surgery & Traumatology, 33 (6). pp. 2573-2577. ISSN: 1633-8065
Abstract
Introduction
Carbon fibre-reinforced polyetheretherketone (CFR-PEEK) plates represent an exciting development within trauma and orthopaedic surgery, offering advantages including radiolucency, material properties similar to bone, and lack of localised tissue reaction. As more call for trials examining their use, there is no data available as to the acceptability of these implants to patients. This study aimed to therefore examine the acceptability of CFR-PEEK plates to patients undergoing fracture surgery.
Methods
This was a prospective cross-sectional survey of patients undergoing surgery for a fracture of the ankle, distal femur, distal radius, or proximal humerus. Once a decision had been made to pursue operative fixation with a plate, patients were provided with descriptions of both CFR-PEEK and stainless steel and titanium metal implants alongside the current clinical evidence. All patients undertook a questionnaire examining their views as to the advantages and disadvantages of CFR-PEEK plates, and whether they would be happy to participate in a trial comparing both.
Results
Ninety-nine patients were happy to participate (64 females, mean age 50). Eighty-seven patients reported that they would want a CFR-PEEK implant for their fracture, and 76 reported that they would be willing to participate in an RCT comparing their use. Commonly reported advantages included radiolucency, low weight and biocompatibility. Disadvantages reported included cost and concerns regarding durability.
Conclusions
This study demonstrates that CFR-PEEK implants would be acceptable to patients undergoing fracture surgery, with high numbers of patients stating that they would be willing to participate in a randomised study examining their use.
Metadata
| Item Type: | Article |
|---|---|
| Authors/Creators: |
|
| Copyright, Publisher and Additional Information: | © The Author(s) 2023. This article is licensed under a Creative Commons Attribution 4.0 International License, which permits use, sharing, adaptation, distribution and reproduction in any medium or format, as long as you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons licence, and indicate if changes were made. The images or other third party material in this article are included in the article's Creative Commons licence, unless indicated otherwise in a credit line to the material. If material is not included in the article's Creative Commons licence and your intended use is not permitted by statutory regulation or exceeds the permitted use, you will need to obtain permission directly from the copyright holder. To view a copy of this licence, visit http://creativecommons.org/licenses/by/4.0/. |
| Keywords: | Carbon fibre; Implant; PEEK; Fracture fixation |
| Dates: |
|
| Institution: | The University of Leeds |
| Academic Units: | The University of Leeds > Faculty of Medicine and Health (Leeds) > School of Medicine (Leeds) > Institute of Rheumatology & Musculoskeletal Medicine (LIRMM) (Leeds) > Orthopaedics (Leeds) The University of Leeds > Faculty of Medicine and Health (Leeds) > School of Medicine (Leeds) > Institute of Rheumatology & Musculoskeletal Medicine (LIRMM) (Leeds) |
| Date Deposited: | 11 Aug 2026 08:21 |
| Last Modified: | 11 Aug 2026 08:21 |
| Published Version: | https://link.springer.com/article/10.1007/s00590-0... |
| Status: | Published |
| Publisher: | Springer Nature |
| Identification Number: | 10.1007/s00590-023-03473-6 |
| Related URLs: | |
| Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:243643 |
Download
Filename: Patient perspective on the use of carbon fibre plates for extremity.pdf
Licence: CC-BY 4.0

CORE (COnnecting REpositories)
CORE (COnnecting REpositories)