Khan, Michelle, Moldestad, Irene Ohlen, Ellison, Peter orcid.org/0000-0003-3741-8219 et al. (3 more authors) (2026) Initial stability of surface vs. full cemented tibial components under cyclic loading. Knee. 104561. ISSN: 0968-0160
Abstract
BACKGROUND: Total Knee Arthroplasty is a common treatment for end-stage osteoarthritis with excellent long-term survival. However, aseptic loosening of the tibial component remains a concern and may be influenced by cementing technique. Radiostereometric analysis studies indicate that early tibial migration increases the risk for later loosening. There is no consensus regarding how the tibial component should be cemented. OBJECTIVES: To compare surface cementation (SC) and full cementation (FC) of the tibial component with respect to migration, micromotion, and bonding strength and to assess correlation between cement thickness and implant movement. METHODS: Using a composite tibia model, we compared SC (n = 5) with FC (n = 5) of the NexGen Stemmed Option tibial baseplate. Groups underwent 20,000 loading cycles at a maximal axial load of 1780 N at a 1 Hz rate. Migration and micromotion were measured with Linear Variable Differential Transformers. Bonding strength was assessed in a push-out test. Parametric statistics were used for group comparisons. RESULTS: Mean anterior migration was 0.7 µm (SD ± 0.8) for FC and -1.3 µm (±1.5) for SC (p = 0.03). Mean anterior micromotion was 1.1 µm (± 0.8) for FC and 12.3 µm (±7.2) for SC (p = 0.03). Posterior implant movement were similar between groups. The FC-group demonstrated higher mean bonding strength (7655 N ± 1613) compared with SC (4541 N ± 1202) (p = 0.009). Greater anterior cement thickness correlated with reduced micromotion (r = -0.7, p = 0.02). CONCLUSION: Full cementation resulted in greater anterior stability and bonding strength compared with surface cementation. These findings suggest that full cementation reduces initial movement for NexGen Stemmed Option tibial baseplates.
Metadata
| Item Type: | Article |
|---|---|
| Authors/Creators: |
|
| Copyright, Publisher and Additional Information: | © 2026 The Author(s). |
| Dates: |
|
| Institution: | The University of York |
| Academic Units: | The University of York > Faculty of Sciences (York) > Electronic Engineering (York) |
| Date Deposited: | 15 Jul 2026 13:00 |
| Last Modified: | 03 Nov 2026 00:38 |
| Published Version: | https://doi.org/10.1016/j.knee.2026.104561 |
| Status: | Published |
| Refereed: | Yes |
| Identification Number: | 10.1016/j.knee.2026.104561 |
| Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:243471 |
Download
Filename: 1-s2.0-S0968016026002413-main.pdf
Description: Initial stability of surface vs. full cemented tibial components under cyclic loading
Licence: CC-BY 2.5

CORE (COnnecting REpositories)
CORE (COnnecting REpositories)