Marcelo Gregorio, R.R. orcid.org/0000-0002-9266-1820, Dastgiri, F. orcid.org/0000-0001-5814-4398, Basharina-Freshville, A. orcid.org/0000-0001-5627-7832 et al. (7 more authors) (2026) Direct in-chamber radon-220 (thoron) emanation measurements for rare-event physics experiments. Journal of Instrumentation, 21 (03). P03027. ISSN: 1748-0221
Abstract
Measuring radon emanation from detector materials is a key method for controlling radon, a significant background in rare-event physics experiments. Methods for measuring radon emanation are well-established but have predominantly focused on the 222Rn isotope, the dominant radon isotope for these backgrounds. However, measurements of 220Rn (thoron), the second most abundant radon isotope, remain relatively unexplored. 220Rn emanation measurements are challenging because the 220Rn must be transferred from the emanation chamber to the active detector within its short 55 s half-life. In this study, a direct in-chamber approach for measuring 220Rn emanation is presented in which the sample is placed directly within the active detector chamber, thereby minimising losses during transfer. The method was demonstrated with a DURRIDGE RAD8 electrostatic radon detector, which measured 220Rn emanation from low-activity thoriated rods with an activity of 76 ± 20 mBq. Compared with a conventional flowthrough 220Rn emanation setup, the in-chamber method increased sensitivity by a factor of 3. Using helium as the carrier gas provided a further sensitivity increase, giving an overall sensitivity gain of ∼ 5. These results indicate that in-chamber 220Rn emanation measurements provide an effective tool for low-background experiments and have the potential to accelerate radon studies by exploiting the shorter half-life of 220Rn.
Metadata
| Item Type: | Article |
|---|---|
| Authors/Creators: |
|
| Copyright, Publisher and Additional Information: | © 2026 The Author(s). Published by IOP Publishing Ltd on behalf of Sissa Medialab. Original content from this work may be used under the terms of the Creative Commons Attribution 4.0 licence. Any further distribution of this work must maintain attribution to the author(s) and the title of the work, journal citation and DOI. http://creativecommons.org/licenses/by/4.0/ |
| Keywords: | Dark Matter detectors (WIMPs, axions, etc.); Materials for gaseous detectors; Gas systems and purification |
| Dates: |
|
| Institution: | The University of Sheffield |
| Academic Units: | The University of Sheffield > Faculty of Science (Sheffield) > School of Mathematical and Physical Sciences |
| Date Deposited: | 30 Mar 2026 11:28 |
| Last Modified: | 30 Mar 2026 11:28 |
| Status: | Published |
| Publisher: | IOP Publishing |
| Refereed: | Yes |
| Identification Number: | 10.1088/1748-0221/21/03/p03027 |
| Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:239615 |
Download
Filename: Marcelo_Gregorio_2026_J._Inst._21_P03027.pdf
Licence: CC-BY 4.0

CORE (COnnecting REpositories)
CORE (COnnecting REpositories)