Coveney, S., Shelley, D., Foster, R. et al. (8 more authors) (2025) Optimising Cardiac Diffusion Tensor Imaging In Vivo: More Directions or Repetitions? Journal of Cardiovascular Magnetic Resonance. ISSN: 1097-6647 (In Press)
Abstract
Background
Cardiac diffusion tensor imaging (cDTI) is sensitive to imaging parameters including the number of unique diffusion encoding directions (ND) and number of repetitions (NR; analogous to number of signal averages or NSA). However, there is no clear guidance for optimising these parameters in the clinical setting.
Methods
Spin echo cDTI data with 2nd order motion compensated diffusion encoding gradients were acquired in ten healthy volunteers on a 3 T MRI scanner with different diffusion encoding schemes in pseudo-randomised order. The data were subsampled to yield 96 acquisition schemes with 6 ≤ ND ≤ 30 and 33 ≤ total number of acquisitions (NAall) ≤ 180. Stratified bootstrapping with robust fitting was performed to assess the accuracy and precision of each acquisition scheme. This was quantified across a mid-ventricular short-axis slice in terms of root mean squared difference (RMSD) with respect to the full reference dataset, and standard deviation (SD) across bootstrap samples respectively.
Results
For the same acquisition time, the ND = 30 schemes had on average 48%, 40%, 34% and 34% lower RMSD and 6.2%, 7.4%, 10% and 5.6% lower SD in MD, FA, HA and |E2A| compared to the ND = 6 schemes. Given a fixed number of high b-value acquisitions, there was a trend towards lower RMSD and SD of MD and FA with increasing numbers of low b-value acquisitions. Higher NAall with longer acquisition times led to improved accuracy in all metrics whereby quadrupling NAall from 40 to 160 volumes led to a 20%, 39%, 11% and 5.4% reduction in RMSD of MD, FA, HA and |E2A| respectively, averaged across six diffusion encoding schemes. Precision was also improved with a corresponding 53%, 50%, 53% and 36% reduction in SD.
Conclusions
We observed that accuracy and precision were enhanced by (i) prioritising number of diffusion encoding directions over number of repetitions given a fixed acquisition time, (ii) acquiring sufficient low b-value data, (iii) using longer protocols where feasible. For clinically relevant protocols, our findings support the use of ND = 30 and NAb50:NAb500 ≥ 1/3 for better accuracy and precision in cDTI parameters. These findings are intended to help guide protocol optimisation for harmonisation of cDTI.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2025 Published by Elsevier Inc. on behalf of Society for Cardiovascular Magnetic Resonance. This is an open access article under the terms of the Creative Commons Attribution License (CC-BY 4.0), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited. |
Keywords: | Cardiac MRI; diffusion tensor imaging; diffusion schemes; diffusion encoding directions; heart; myocardium; tissue microstructure |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Medicine and Health (Leeds) > School of Medicine (Leeds) |
Funding Information: | Funder Grant number Wellcome Trust 219536/Z/19/Z British Heart Foundation Accounts Payable - Gloria Sankey PG/19/1/34076 |
Depositing User: | Symplectic Publications |
Date Deposited: | 09 Sep 2025 12:45 |
Last Modified: | 09 Sep 2025 12:45 |
Status: | In Press |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.jocmr.2025.101951 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:231259 |