Ragy, O., Abass, W., Kanigicherla, D.A.K. et al. (6 more authors) (2025) PLA2R autoantibodies, a multifaceted biomarker in nephrotic syndrome and membranous nephropathy. Nephrology Dialysis Transplantation, 40 (8). pp. 1458-1469. ISSN: 0931-0509
Abstract
The phospholipase A2 receptor antibody (PLA2R-Ab) test is a valuable first-line diagnostic tool for primary membranous nephropathy (MN), helping to identify PLA2R-related MN and potentially eliminating the need for a kidney biopsy in some individuals. By reducing the reliance on biopsies, the test streamlines diagnosis and improves patient care. However, determining the optimal PLA2R measurement method and cut-off is critical to maximizing the benefits of the test and minimizing any harms. A systematic review and meta-analysis were performed to evaluate serum- and urine-based biomarkers for distinguishing between PLA2R-related MN and non-PLA2R MN. Searches were conducted in databases including Medline, Embase, Cochrane Library, Scopus, Web of Science, International HTA Database and ClinicalTrials.gov. The methodology followed Cochrane-recommended guidelines for systematic reviews and meta-analyses, and the QUADAS-2 tool was utilized to assess the overall risk of bias. Ninety-one studies met the eligibility criteria for inclusion in the review. Of these, 38 studies reporting the accuracy of the PLA2R-Ab test using the EUROIMMUN enzyme-linked immunosorbent assay (ELISA) method and 27 using the EUROIMMUN immunofluorescence (IF) method were suitable for meta-analysis. The pooled sensitivity and specificity of EUROIMMUN ELISA at a cut-off value of 20 RU/mL were 0.64 [95% confidence interval (CI) 0.56–0.72] and 94.7% (95% CI 90.5–97.1%), respectively. The pooled sensitivity and specificity of EUROIMMUN IF at a threshold of 1:10 was 0.69 (95% CI 0.637–0.739) and 0.98 (95% CI 0.931–0.994), respectively. Risk of bias was higher for studies evaluating the IF compared with ELISA test. We also explored whether the timing of the index test had an impact on the pooled diagnostic accuracy results; no significant differences were found. By evaluating the specificity and sensitivity of EUROIMMUN ELISA PLA2R-Ab and IF, we demonstrate that at ELISA levels ≥20 RU/mL, alongside thorough secondary screening, a kidney biopsy may be unnecessary. However, lower or negative levels still warrant a biopsy.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © The Author(s) 2025. This is an open access article under the terms of the Creative Commons Attribution License (CC-BY-NC 4.0), which permits unrestricted use, distribution and reproduction in any medium, provided the original work is properly cited. |
Keywords: | non-invasive biomarkers, PLA2R, primary membranous nephropathy, sensitivity and specificity |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Medicine and Health (Leeds) > School of Medicine (Leeds) |
Funding Information: | Funder Grant number NIHR National Inst Health Research PO 000317655 |
Depositing User: | Symplectic Publications |
Date Deposited: | 12 Sep 2025 15:03 |
Last Modified: | 12 Sep 2025 15:03 |
Status: | Published |
Publisher: | Oxford University Press |
Identification Number: | 10.1093/ndt/gfaf012 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:231049 |
Download
Filename: PLA2R autoantibodies, a multifaceted biomarker in nephrotic syndrome and membranous nephropathy.pdf
Licence: CC-BY-NC 4.0