Grafton-Clarke, C. orcid.org/0000-0002-8537-0806, Thornton, G. orcid.org/0000-0003-3289-2413, Fidock, B. et al. (13 more authors) (2023) Mitral regurgitation quantification by cardiac magnetic resonance imaging (MRI) remains reproducible between software solutions [version 3; peer review: 2 approved]. Wellcome Open Research, 6. 253. ISSN 2398-502X
Abstract
Background: The reproducibility of mitral regurgitation (MR) quantification by cardiovascular magnetic resonance (CMR) imaging using different software solutions remains unclear. This research aimed to investigate the reproducibility of MR quantification between two software solutions: MASS (version 2019 EXP, LUMC, Netherlands) and CAAS (version 5.2, Pie Medical Imaging). Methods: CMR data of 35 patients with MR (12 primary MR, 13 mitral valve repair/replacement, and ten secondary MR) was used. Four methods of MR volume quantification were studied, including two 4D-flow CMR methods (MRMVAV and MRJet) and two non-4D-flow techniques (MRStandard and MRLVRV). We conducted within-software and inter-software correlation and agreement analyses. Results: All methods demonstrated significant correlation between the two software solutions: MRStandard (r=0.92, p<0.001), MRLVRV (r=0.95, p<0.001), MRJet (r=0.86, p<0.001), and MRMVAV (r=0.91, p<0.001). Between CAAS and MASS, MRJet and MRMVAV, compared to each of the four methods, were the only methods not to be associated with significant bias. Conclusions: We conclude that 4D-flow CMR methods demonstrate equivalent reproducibility to non-4D-flow methods but greater levels of agreement between software solutions.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2023 Grafton-Clarke C et al. This is an open access work distributed under the terms of the Creative Commons Attribution License, (https://creativecommons.org/licenses/by/4.0/) which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited. |
Keywords: | Magnetic resonance imaging; Mitral valve insufficiency; Reproducibility of results. |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > Department of Infection, Immunity and Cardiovascular Disease |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 14 Jun 2023 09:46 |
Last Modified: | 14 Jun 2023 09:46 |
Status: | Published |
Publisher: | F1000 Research Ltd |
Refereed: | Yes |
Identification Number: | 10.12688/wellcomeopenres.17200.3 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:200354 |