Veldman, J.K., van Kesteren, Z., Gunwhy, E.R. orcid.org/0000-0002-5608-9812 et al. (6 more authors) (2023) Accuracy of abdominal organ motion estimation in radiotherapy using the right hemidiaphragm top as a surrogate during prolonged breath‐holds quantified with MRI. Medical Physics, 50 (6). pp. 3299-3310. ISSN 0094-2405
Abstract
BACKGROUND: Respiratory motion presents a challenge in radiotherapy of thoracic and upper abdominal tumors. Techniques to account for respiratory motion include tracking. Using magnetic resonance imaging (MRI) guided radiotherapy systems, tumors can be tracked continuously. Using conventional linear accelerators, tracking of lung tumors is possible by determining tumor motion on kilo voltage (kV) imaging. But tracking of abdominal tumors with kV imaging is hampered by limited contrast. Therefore, surrogates for the tumor are used. One of the possible surrogates is the diaphragm. However, there is no universal method for establishing the error when using a surrogate and there are particular challenges in establishing such errors during free breathing (FB). Prolonged breath-holding might address these challenges. PURPOSE: The aim of this study was to quantify the error when using the right hemidiaphragm top (RHT) as surrogate for abdominal organ motion during prolonged breath-holds (PBH) for possible application in radiation treatments. METHODS: Fifteen healthy volunteers were trained to perform PBHs in two subsequent MRI sessions (PBH-MRI1 and PBH-MRI2). From each MRI acquisition, we selected seven images (dynamics) to determine organ displacement during PBH by using deformable image registration (DIR). On the first dynamic, the RHT, right and left hemidiaphragm, liver, spleen and right and left kidney were segmented. We used the deformation vector fields (DVF), generated by DIR, to determine the displacement of each organ between two dynamics in inferior-superior (IS), anterior-posterior (AP), left-right (LR) direction and we calculated the 3D vector magnitude (|d|). The displacements of the RHT, both hemidiaphragms and the abdominal organs were compared using a linear fit to determine the correlation (R2 of the fit) and the displacement ratio (DR, slope of the fit) between displacements of the RHT and each organ. We quantified the median difference between the DRs of PBH-MRI1 and PBH-MRI2 for each organ. Additionally, we estimated organ displacement in the second PBH by applying the DR from the first PBH to the displacement of the RHT measured during the second PBH. We compared the estimated organ displacement to the measured organ displacement during the second PBH. The difference between the two values was defined as the estimation error of using the RHT as a surrogate and assuming a constant DR over MRI sessions. RESULTS: The linear relationships were confirmed by the high R2 values of the linear fit between the displacements of the RHT and the abdominal organs (R2 > 0.96) in the IS and AP direction and |d|, and high to moderate correlations in the LR direction (0.93 > R2 > 0.64). The median DR difference between PBH-MRI1 and PBH-MRI2 varied between 0.13 and 0.31 for all organs. The median estimation error of the RHT as a surrogate varied between 0.4 and 0.8 mm/min for all organs. CONCLUSION: The RHT could serve as an accurate surrogate for abdominal organ motion during radiation treatments, for example, in tracking, provided the error of the RHT as motion surrogate is taken into account in the margins. TRIAL REGISTRATION: The study was registered in the Netherlands Trial Register (NL7603).
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2023 Amsterdam UMC - location AMC. Medical Physics published by Wiley Periodicals LLC on behalf of American Association of Physicists in Medicine. This is an open access article under the terms of the Creative Commons Attribution-NonCommercial-NoDerivs License, which permits use and distribution in any medium, provided the original work is properly cited, the use is non-commercial and no modifications or adaptations are made (https://creativecommons.org/licenses/by-nc-nd/4.0/). |
Keywords: | MRI; breathing control; motion surrogate |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > Department of Infection, Immunity and Cardiovascular Disease |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 05 Jun 2023 11:10 |
Last Modified: | 02 Oct 2024 10:53 |
Status: | Published |
Publisher: | Wiley |
Refereed: | Yes |
Identification Number: | 10.1002/mp.16403 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:199667 |