Slevin, F orcid.org/0000-0002-7176-904X, Rieu, R, Beasley, M et al. (10 more authors) (2023) Evaluation of the impact of teaching on delineation variation during a virtual stereotactic ablative radiotherapy contouring workshop. Journal of Radiotherapy in Practice, 22. e19. ISSN 1460-3969
Abstract
Introduction:
Variation in delineation of target volumes/organs at risk (OARs) is well recognised in radiotherapy and may be reduced by several methods including teaching. We evaluated the impact of teaching on contouring variation for thoracic/pelvic stereotactic ablative radiotherapy (SABR) during a virtual contouring workshop.
Materials and methods:
Target volume/OAR contours produced by workshop participants for three cases were evaluated against reference contours using DICE similarity coefficient (DSC) and line domain error (LDE) metrics. Pre- and post-workshop DSC results were compared using Wilcoxon signed ranks test to determine the impact of teaching during the workshop.
Results:
Of 50 workshop participants, paired pre- and post-workshop contours were available for 21 (42%), 20 (40%) and 22 (44%) participants for primary lung cancer, pelvic bone metastasis and pelvic node metastasis cases, respectively. Statistically significant improvements post-workshop in median DSC and LDE results were observed for 6 (50%) and 7 (58%) of 12 structures, respectively, although the magnitude of DSC/LDE improvement was modest in most cases. An increase in median DSC post-workshop ≥0·05 was only observed for GTVbone, IGTVlung and SacralPlex, and reduction in median LDE > 1 mm was only observed for GTVbone, CTVbone and SacralPlex. Post-workshop, median DSC values were >0·7 for 75% of structures. For 92% of the structures, post-workshop contours were considered to be acceptable or within acceptable variation following review by the workshop faculty.
Conclusions:
This study has demonstrated that virtual SABR contouring training is feasible and was associated with some improvements in contouring variation for multiple target volumes/OARs.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © The Author(s), 2021. This is an author produced version of an article published in Journal of Radiotherapy in Practice. Uploaded in accordance with the publisher's self-archiving policy. |
Keywords: | Stereotactic Ablative Radiotherapy; contouring; delineation; contouring workshop; contour variability; teaching impact |
Dates: |
|
Institution: | The University of Leeds |
Depositing User: | Symplectic Publications |
Date Deposited: | 28 Oct 2022 11:42 |
Last Modified: | 25 Jan 2023 10:39 |
Status: | Published |
Publisher: | Cambridge University Press (CUP) |
Identification Number: | 10.1017/s1460396921000583 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:192433 |