Synthetic biodegradable alternatives to the use of the amniotic membrane for corneal regeneration: assessment of local and systemic toxicity in rabbits.

Ramachandran, C., Sangwan, V.S., Ortega, I. et al. (4 more authors) (2019) Synthetic biodegradable alternatives to the use of the amniotic membrane for corneal regeneration: assessment of local and systemic toxicity in rabbits. British Journal of Ophthalmology, 103 (2). pp. 286-292. ISSN 0007-1161

Abstract

Metadata

Item Type: Article
Authors/Creators:
Copyright, Publisher and Additional Information:

© Author(s) (or their employer(s)) 2018. This is an author produced version of a paper subsequently published in the British Journal of Ophthalmology. Uploaded in accordance with the publisher's self-archiving policy.

Keywords: Cornea; ocular surface; stem cells
Dates:
  • Published: February 2019
  • Published (online): 18 October 2018
  • Accepted: 17 September 2018
Institution: The University of Sheffield
Academic Units: The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Materials Science and Engineering (Sheffield)
The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > School of Clinical Dentistry (Sheffield)
Funding Information:
Funder
Grant number
ENGINEERING AND PHYSICAL SCIENCE RESEARCH COUNCIL (EPSRC)
EP/I017801/1
Depositing User: Symplectic Sheffield
Date Deposited: 05 Nov 2018 16:14
Last Modified: 10 May 2024 11:10
Status: Published
Publisher: BMJ Publishing Group
Refereed: Yes
Identification Number: 10.1136/bjophthalmol-2018-312055
Related URLs:
Open Archives Initiative ID (OAI ID):

Export