Paterson, Max and Dawson, John F orcid.org/0000-0003-4537-9977 (2018) An Investigation into Alternatives to the CISPR 12 Full Vehicle Measurement Method. In: 2018 International Symposium on Electromagnetic Compatibility - EMC EUROPE. 2018 International Symposium on Electromagnetic Compatibility - EMC EUROPE, 27-30 Aug 2018 EMC Europe . , NLD , pp. 885-889.
Abstract
The current CISPR 12 method has been shown to under estimate vehicle radiated emissions by up to 30 dB. This paper describes and presents a possible alternative test method to the current CISPR 12 procedure. The initial results from investigations into the use of the use of the ’Test Wire Method’ are presented, where a reduction in the average error of approximately 8dB compared to the CISPR 12 method has been recorded.
Metadata
Item Type: | Proceedings Paper |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | Accepted 11 April 2018 |
Dates: |
|
Institution: | The University of York |
Academic Units: | The University of York > Faculty of Sciences (York) > Electronic Engineering (York) |
Depositing User: | Pure (York) |
Date Deposited: | 14 May 2018 11:30 |
Last Modified: | 19 Dec 2024 00:25 |
Published Version: | https://doi.org/10.1109/EMCEurope.2018.8485097 |
Status: | Published |
Series Name: | EMC Europe |
Identification Number: | 10.1109/EMCEurope.2018.8485097 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:130813 |
Download
Filename: Paterson_2018_postprint.pdf
Description: Paterson_2018_postprint