Zhang, Z orcid.org/0000-0003-0204-3867, Zhang, L and Yang, G-Z (2017) A computationally efficient method for hand–eye calibration. International Journal of Computer Assisted Radiology and Surgery, 12 (10). pp. 1775-1787. ISSN 1861-6410
Abstract
Purpose: Surgical robots with cooperative control and semiautonomous features have shown increasing clinical potential, particularly for repetitive tasks under imaging and vision guidance. Effective performance of an autonomous task requires accurate hand–eye calibration so that the transformation between the robot coordinate frame and the camera coordinates is well defined. In practice, due to changes in surgical instruments, online hand–eye calibration must be performed regularly. In order to ensure seamless execution of the surgical procedure without affecting the normal surgical workflow, it is important to derive fast and efficient hand–eye calibration methods. Methods: We present a computationally efficient iterative method for hand–eye calibration. In this method, dual quaternion is introduced to represent the rigid transformation, and a two-step iterative method is proposed to recover the real and dual parts of the dual quaternion simultaneously, and thus the estimation of rotation and translation of the transformation. Results: The proposed method was applied to determine the rigid transformation between the stereo laparoscope and the robot manipulator. Promising experimental and simulation results have shown significant convergence speed improvement to 3 iterations from larger than 30 with regard to standard optimization method, which illustrates the effectiveness and efficiency of the proposed method.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © The Author(s) 2017. Open Access. This article is distributed under the terms of the Creative Commons Attribution 4.0 International License (http://creativecommons.org/licenses/by/4.0/), which permits unrestricted use, distribution, and reproduction in any medium, provided you give appropriate credit to the original author(s) and the source, provide a link to the Creative Commons license, and indicate if changes were made. |
Keywords: | Minimally invasive surgery; Robot–camera calibration; Hand–eye calibration; Optimization |
Dates: |
|
Institution: | The University of Leeds |
Depositing User: | Symplectic Publications |
Date Deposited: | 21 Jul 2017 12:31 |
Last Modified: | 19 Oct 2017 15:52 |
Status: | Published |
Publisher: | Springer Verlag |
Identification Number: | 10.1007/s11548-017-1646-x |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:119261 |