Murray, LJ orcid.org/0000-0003-0658-6455, Cosgrove, V, Lilley, J et al. (5 more authors) (2014) Developing a class solution for Prostate Stereotactic Ablative Body Radiotherapy (SABR) using Volumetric Modulated Arc Therapy (VMAT). Radiotherapy and Oncology, 110 (2). pp. 298-302. ISSN 0167-8140
Abstract
Background and purpose To develop a class solution for prostate Stereotactic Ablative Radiotherapy (SABR) using Volumetric Modulated Arc Therapy (VMAT). Materials and methods Seven datasets were used to compare plans using one 360° arc (1FA), one 210° arc (1PA), two full arcs and two partial arcs. Subsequently using 1PA, fifteen datasets were compared using (i) 6 mm CTV–PTV margins, (ii) 8 mm CTV–PTV margins and (iii) including the proximal SV within the CTV. Monaco™ 3.2 (Elekta™) was used for planning with the Agility™ MLC system (Elekta™). Results Highly conformal plans were produced using all four arc arrangements. Compared to 1FA, 1PA resulted in significantly reduced rectal doses, and monitor units and estimated delivery times were reduced in six of seven cases. Using 6 mm CTV–PTV margins, planning constraints were met for all fifteen datasets. Using 8 mm margins required relaxation of the uppermost bladder constraint in three cases to achieve adequate coverage, and, compared to 6 mm margins, rectal and bladder doses significantly increased. Including the proximal SV required relaxation of the uppermost bladder and rectal constraints in two cases, and rectal and bladder doses significantly increased. Conclusions Prostate SABR VMAT is optimal using 1PA. 6 mm CTV–PTV margins, compatible with daily fiducial-based IGRT, are consistently feasible in terms of target objectives and OAR constraints.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | Copyright © 2013 The Authors. Published by Elsevier Ireland Ltd Open access under CC BY-NC-ND license. |
Keywords: | Image Guided Radio Therapy (IGRT); Prostate cancer; Stereotactic Ablative Body Radiotherapy (SABR); Volumetric Modulated Arc Therapy (VMAT) |
Dates: |
|
Institution: | The University of Leeds |
Depositing User: | Symplectic Publications |
Date Deposited: | 03 Jan 2017 16:21 |
Last Modified: | 03 Jan 2017 16:21 |
Published Version: | https://doi.org/10.1016/j.radonc.2013.10.036 |
Status: | Published |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.radonc.2013.10.036 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:110036 |