Dellimore, K.H.J., Mank, A.J.G., Wojnowski, J. et al. (2 more authors) (2016) Evaluation of catheter-induced tribological damage to porcine aorta using infra-red spectroscopy. Biotribology, 7. pp. 11-21.
Abstract
© 2016 Elsevier Ltd Studies were carried out to assess the potential of attenuated total internal reflection Fourier transform infrared (ATR)-FTIR spectroscopy as a tool for evaluating mechanical-tribological damage to the blood vessel wall occurring during simulated endovascular catheterization on fresh ex-vivo porcine aortic tissue. It is envisaged that this method could be used in laboratory tests to quantitatively compare catheters or catheterization approaches with regard to their effect on damage to the aorta wall. Tribological damage was induced on the tissue. Obvious changes were visible in the FTIR spectra as well as the friction coefficient as a function of increasing damage. In particular, the spectral changes due to damage to the outermost layer of the tissue were significant, provided appropriate sample conditioning was performed. These changes, which correlated with a reduction in friction coefficient, can be attributed to the removal of successive layers of tissue as a result of a wear process. In conclusion, FTIR spectroscopy was found to be a reliable and effective measurement technique for quantifying catheter-induced tissue damage, allowing very repeatable spectra to be obtained from the tissue up to 36 h after excision with no major spectral changes observed during this time frame due to tissue age.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2016 Elsevier. This is an author produced version of a paper subsequently published in Biotribology. Uploaded in accordance with the publisher's self-archiving policy. Article available under the terms of the CC-BY-NC-ND licence (https://creativecommons.org/licenses/by-nc-nd/4.0/) |
Keywords: | Endovascular catheters; ATR-FTIR spectroscopy; Vascular trauma; Tissue damage characterization; Catheter-induced damage; Mechanical damage quantification |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield) |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 12 Oct 2016 12:38 |
Last Modified: | 12 Aug 2017 06:27 |
Published Version: | http://dx.doi.org/10.1016/j.biotri.2016.07.002 |
Status: | Published |
Publisher: | Elsevier |
Refereed: | Yes |
Identification Number: | 10.1016/j.biotri.2016.07.002 |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:105867 |
Download
Filename: Catheter-induced tribological damage_post_rev_v5.pdf
Licence: CC-BY-NC-ND 4.0