Lamberto, G. orcid.org/0000-0001-7038-2655, Martelli, S., Cappozzo, A. et al. (1 more author) (2017) To what extent is joint and muscle mechanics predicted by musculoskeletal models sensitive to soft tissue artefacts? Journal of Biomechanics, 62. pp. 68-76. ISSN 0021-9290
Abstract
Musculoskeletal models are widely used to estimate joint kinematics, intersegmental loads, and muscle and joint contact forces during movement. These estimates can be heavily affected by the soft tissue artefact (STA) when input positional data are obtained using stereophotogrammetry, but this aspect has not yet been fully characterised for muscle and joint forces. This study aims to assess the sensitivity to the STA of three open-source musculoskeletal models, implemented in OpenSim. A baseline dataset of marker trajectories was created for each model from experimental data of one healthy volunteer. Five hundred STA realizations were then statistically generated using a markerdependent model of the pelvis and lower limb artefact and added to the baseline data. The STA's impact on the musculoskeletal model estimates was finally quantified using a Monte Carlo analysis. The modelled STA distributions were in line with the literature. Observed output variations were comparable across the three models, and sensitivity to the STA was evident for most investigated quantities. Shape, magnitude and timing of the joint angle and moment time histories were not significantly affected throughout the entire gait cycle, whereas magnitude variations were observed for muscle and joint forces. Ranges of contact force variations differed between joints, with hip variations up to 1.8 times body weight observed. Variations of more than 30% were observed for some of the muscle forces. In conclusion, musculoskeletal simulations using stereophotogrammetry may be safely run when only interested in overall output patterns. Caution should be paid when more accurate estimated values are needed.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | © 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/). |
Keywords: | Joint contact load; Musculoskeletal modelling; Soft tissue artefact; Probabilistic analysis |
Dates: |
|
Institution: | The University of Sheffield |
Academic Units: | The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield) |
Funding Information: | Funder Grant number ENGINEERING AND PHYSICAL SCIENCE RESEARCH COUNCIL (EPSRC) EP/K03877X/1 EUROPEAN COMMISSION - FP6/FP7 MDPAEDIGREE - 600932 |
Depositing User: | Symplectic Sheffield |
Date Deposited: | 08 Aug 2016 14:22 |
Last Modified: | 08 Jul 2020 10:19 |
Published Version: | http://dx.doi.org/10.1016/j.jbiomech.2016.07.042 |
Status: | Published |
Publisher: | Elsevier |
Refereed: | Yes |
Identification Number: | 10.1016/j.jbiomech.2016.07.042 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:103365 |