About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: A 3D zero-strain study

This is the latest version of this eprint.

Dall'Ara, E., Barber, D. and Viceconti, M. (2014) About the inevitable compromise between spatial resolution and accuracy of strain measurement for bone tissue: A 3D zero-strain study. Journal of Biomechanics, 47 (12). 2956 - 2963. ISSN 0021-9290

Abstract

Metadata

Authors/Creators:
  • Dall'Ara, E.
  • Barber, D.
  • Viceconti, M.
Copyright, Publisher and Additional Information: © 2014 Elsevier Ltd. This is an author produced version of a paper subsequently published in Journal of Biomechanics. Uploaded in accordance with the publisher's self-archiving policy. Article available under the terms of the CC-BY-NC-ND licence (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Keywords: Bone; DVC; MicroCT; Registration; Strain
Dates:
  • Published: 22 September 2014
Institution: The University of Sheffield
Academic Units: The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield)
The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > Department of Infection, Immunity and Cardiovascular Disease
Depositing User: Symplectic Sheffield
Date Deposited: 07 Oct 2015 15:36
Last Modified: 03 Nov 2017 16:43
Published Version: http://dx.doi.org/10.1016/j.jbiomech.2014.07.019
Status: Published
Publisher: Elsevier
Refereed: Yes
Identification Number: https://doi.org/10.1016/j.jbiomech.2014.07.019

Available Versions of this Item

Export

Statistics