Welberry Smith, MP, Zougman, A orcid.org/0000-0002-7168-1339, Cairns, DA orcid.org/0000-0002-2338-0179 et al. (9 more authors) (2013) Serum aminoacylase-1 is a novel biomarker with potential prognostic utility for long-term outcome in patients with delayed graft function following renal transplantation. Kidney International, 84 (6). pp. 1214-1225. ISSN 0085-2538
Abstract
Early identification and prognostic stratification of delayed graft function following renal transplantation has significant potential to improve outcome. Mass spectrometry analysis of serum samples, before and on day 2 post transplant from five patients with delayed graft function and five with an uncomplicated transplant, identified aminoacylase-1 (ACY-1) as a potential outcome biomarker. Following assay development, analysis of longitudinal samples from an initial validation cohort of 55 patients confirmed that the ACY-1 level on day 1 or 2 was a moderate predictor of delayed graft function, similar to serum creatinine, complementing the strongest predictor cystatin C. A further validation cohort of 194 patients confirmed this association with area under ROC curves (95% CI) for day 1 serum (138 patients) of 0.74 (0.67–0.85) for ACY-1, 0.9 (0.84–0.95) for cystatin C, and 0.93 (0.88–0.97) for both combined. Significant differences in serum ACY-1 levels were apparent between delayed, slow, and immediate graft function. Analysis of long-term follow-up for 54 patients with delayed graft function showed a highly significant association between day 1 or 3 serum ACY-1 and dialysis-free survival, mainly associated with the donor–brain–dead transplant type. Thus, proteomic analysis provides novel insights into the potential clinical utility of serum ACY-1 levels immediately post transplantation, enabling subdivision of patients with delayed graft function in terms of long-term outcome. Our study requires independent confirmation.