Keeling, AJ, Brunton, PA and Holt, RJ (2014) An in vitro study into the accuracy of a novel method for recording the mandibular transverse horizontal axis. Journal of Dentistry, 42 (2). pp. 122-128. ISSN 0300-5712
Abstract
OBJECTIVES: To assess the accuracy of a novel, non-invasive method for determining the axis of rotation of articulated dental study casts. METHOD: A 3D structured light scanner was constructed using a projector and two CMOS cameras. Dental stone casts were arbitrarily mounted on an average value articulator. With the teeth together, sets of 10 scans were taken from three different viewpoints. Each scan captured approximately six upper teeth and six lower teeth. The teeth were then propped open, creating 10mm of incisal separation, and the three sets of 10 scans were repeated. From each pair of scans an axis of rotation was calculated using custom software. A total of 900 axes were created this way. The locations of these axes were plotted in sagittal planes located 57.5mm left and right of the midline to represent the position of the temporo-mandibular joints (TMJs). The accuracy of axis location was then assessed. RESULTS: The average radius of error of the individual axes, compared to the real axis, was 2.65 ± 1.01 mm. 61.3% of the axes lay within 3mm of the true axis, and 99.2% of the axes lay within 5mm of the true axis. CONCLUSIONS: The accuracy of this method is clinically acceptable. Further studies are required to confirm the accuracy of the virtual inter-occlusal records at the level of the dentition. Clinical studies are then indicated to determine whether the transverse horizontal axis on a patient can similarly be determined.
Metadata
Item Type: | Article |
---|---|
Authors/Creators: |
|
Copyright, Publisher and Additional Information: | (c) 2013 Elsevier Ltd. All rights reserved. This is an author produced version of a paper published in Journal of Dentistry. Uploaded in accordance with the publisher's self-archiving policy. |
Keywords: | Articulation; Axis; Virtual, Occlusion |
Dates: |
|
Institution: | The University of Leeds |
Academic Units: | The University of Leeds > Faculty of Engineering & Physical Sciences (Leeds) > School of Mechanical Engineering (Leeds) > Institute of Engineering Systems and Design (iESD) (Leeds) The University of Leeds > Faculty of Medicine and Health (Leeds) > School of Dentistry (Leeds) > Restorative Dentistry (Leeds) |
Depositing User: | Symplectic Publications |
Date Deposited: | 21 Oct 2015 09:29 |
Last Modified: | 16 Jan 2018 16:03 |
Published Version: | http://dx.doi.org/10.1016/j.jdent.2013.11.019 |
Status: | Published |
Publisher: | Elsevier |
Identification Number: | 10.1016/j.jdent.2013.11.019 |
Related URLs: | |
Open Archives Initiative ID (OAI ID): | oai:eprints.whiterose.ac.uk:87979 |