Goode, C. D. and Lam, D. (2008) Concrete - filled steel tube columns - tests compared with Eurocode 4. In: Composite Construction VI, July 20-24, 2008, Devil's Thumb Ranch, Colorado, USA.
Full text available as:
|
Text
filled_steel_tube_columns_Lam.pdf Available under License : See the attached licence file. Download (296Kb) |
Abstract
This paper summarises the data from 1819 tests on concrete-filled steel tube columns and compares their failure load with the prediction of Eurocode 4. The full data is given on the website http://web.ukonline.co.uk/asccs2 . The comparison with Eurocode 4 is discussed and shows that Eurocode 4 can be used with confidence and generally gives good agreement with test results, the average Test/EC4 ratio for all tests being 1.11. The Eurocode 4 limitations on concrete strength could be safely extended to concrete with a cylinder strength of 75 N/mm2 for circular sections and 60 N/mm2 for rectangular sections.