Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment.

Shepherd, SJ, Beggs, CB, Smith, CF, Kerr, KG, Noakes, CJ and Sleigh, PA (2010) Effect of negative air ions on the potential for bacterial contamination of plastic medical equipment. BMC Infectious Diseases, 10 (92). ISSN 1471-2334

Full text available as:
[img]
Preview
Text
Shepherd-BMC-2010.pdf
Available under licence : See the attached licence file.

Download (891Kb)

Abstract

In recent years there has been renewed interest in the use of air ionizers to control the spread of infection in hospitals and a number of researchers have investigated the biocidal action of ions in both air and nitrogen. By comparison, the physical action of air ions on bacterial dissemination and deposition has largely been ignored. However, there is clinical evidence that air ions might play an important role in preventing the transmission of Acinetobacter infection. Although the reasons for this are unclear, it is hypothesized that a physical effect may be responsible: the production of air ions may negatively charge items of plastic medical equipment so that they repel, rather than attract, airborne bacteria. By negatively charging both particles in the air and items of plastic equipment, the ionizers minimize electrostatic deposition on these items. In so doing they may help to interrupt the transmission of Acinetobacter infection in certain healthcare settings such as intensive care units.

Item Type: Article
Copyright, Publisher and Additional Information: © 2010 Shepherd et al; licensee BioMed Central Ltd. This is an Open Access article distributed under the terms of the Creative Commons Attribution License (http://creativecommons.org/licenses/by/2.0), which permits unrestricted use, distribution, and reproduction in any medium, provided the original work is properly cited.
Keywords: Acinetobacter, Air, Air Microbiology, Electricity, Equipment and Supplies, Humans, Infection Control, Ions, Plastics
Institution: The University of Leeds
Academic Units: The University of Leeds > Faculty of Engineering (Leeds) > School of Civil Engineering (Leeds)
The University of Leeds > Faculty of Engineering (Leeds) > School of Civil Engineering (Leeds) > Inst for Pathogen Control Engineering (Leeds)
Depositing User: Symplectic Publications
Date Deposited: 21 Jul 2011 15:45
Last Modified: 09 Jun 2014 18:04
Status: Published
Publisher: http://dx.doi.org/10.1186/1471-2334-10-92
Identification Number: 10.1186/1471-2334-10-92
URI: http://eprints.whiterose.ac.uk/id/eprint/43161

Actions (repository staff only: login required)