Energy Saving and Carbon Reduction in the Operation Stage of Cross Laminated Timber Residential Buildings in China

Guo, H., Liu, Y., Chang, W.-S. orcid.org/0000-0002-2218-001X et al. (2 more authors) (2017) Energy Saving and Carbon Reduction in the Operation Stage of Cross Laminated Timber Residential Buildings in China. Sustainability, 9 (2). 292.

Abstract

Metadata

Authors/Creators:
Copyright, Publisher and Additional Information: © 2017 by the authors; licensee MDPI, Basel, Switzerland. This article is an open access article distributed under the terms and conditions of the Creative Commons Attribution (CC BY) license (http://creativecommons.org/licenses/by/4.0/).
Keywords: carbon reduction; energy saving; Cross Laminated Timber (CLT); residential building
Dates:
  • Accepted: 15 February 2017
  • Published (online): 17 February 2017
  • Published: 17 February 2017
Institution: The University of Sheffield
Academic Units: The University of Sheffield > Faculty of Social Sciences (Sheffield) > School of Architecture (Sheffield)
Depositing User: Symplectic Sheffield
Date Deposited: 13 Dec 2017 14:17
Last Modified: 13 Dec 2017 14:17
Published Version: https://doi.org/10.3390/su9020292
Status: Published
Publisher: MDPI
Refereed: Yes
Identification Number: https://doi.org/10.3390/su9020292

Export

Statistics