Hemodynamic parameters that may predict false-lumen growth in type-B aortic dissection after endovascular repair: A preliminary study on long-term multiple follow-ups

Xu, H., Li, Z., Dong, H. et al. (6 more authors) (2017) Hemodynamic parameters that may predict false-lumen growth in type-B aortic dissection after endovascular repair: A preliminary study on long-term multiple follow-ups. Medical Engineering & Physics, 50. pp. 12-21. ISSN 1350-4533

Abstract

Metadata

Authors/Creators:
Copyright, Publisher and Additional Information: © 2017 Elsevier. This is an author produced version of a paper subsequently published in Medical Engineering & Physics. Uploaded in accordance with the publisher's self-archiving policy. Article available under the terms of the CC-BY-NC-ND licence (https://creativecommons.org/licenses/by-nc-nd/4.0/)
Keywords: Aortic dissection; Hemodynamics; Endovascular procedures