Experimental Validation of DXA-based Finite Element models for prediction of femoral strength

Dall'Ara, E. orcid.org/0000-0003-1471-5077, Eastell, R.E., Viceconti, M.V. orcid.org/0000-0002-2293-1530 et al. (2 more authors) (2016) Experimental Validation of DXA-based Finite Element models for prediction of femoral strength. Journal of the Mechanical Behavior of Biomedical Materials, 63. pp. 17-25. ISSN 1751-6161

Abstract

Metadata

Authors/Creators:
Copyright, Publisher and Additional Information: & 2016 The Authors. Published by Elsevier Ltd. This is an open access article under the CC BY license (http://creativecommons.org/licenses/by/4.0/)
Keywords: Femur; aBMD; DXA; Finite Element; Bone strength; validation
Dates:
  • Accepted: 2 June 2016
  • Published (online): 10 June 2016
  • Published: October 2016
Institution: The University of Sheffield
Academic Units: The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Mechanical Engineering (Sheffield)
The University of Sheffield > Faculty of Medicine, Dentistry and Health (Sheffield) > Department of Human Metabolism (Sheffield)
Funding Information:
FunderGrant number
ENGINEERING AND PHYSICAL SCIENCE RESEARCH COUNCIL (EPSRC)EP/K03877X/1
Depositing User: Symplectic Sheffield
Date Deposited: 03 Jun 2016 14:10
Last Modified: 11 Apr 2017 02:25
Published Version: http://dx.doi.org/10.1016/j.jmbbm.2016.06.004
Status: Published
Publisher: Elsevier
Refereed: Yes
Identification Number: https://doi.org/10.1016/j.jmbbm.2016.06.004

Export

Statistics