Effect of airgap length on electromagnetic performance of surface mounted permanent magnet Vernier machine

Kana Padinharu, D.K., Li, G.-J. orcid.org/0000-0002-5956-4033, Zhu, Z.Q. et al. (3 more authors) (2020) Effect of airgap length on electromagnetic performance of surface mounted permanent magnet Vernier machine. In: Proceedings of 2020 International Conference on Electrical Machines (ICEM). 2020 International Conference on Electrical Machines (ICEM), 23-26 Aug 2020, Online conference. IEEE , pp. 1882-1888. ISBN 9781728199467

Abstract

Metadata

Authors/Creators:
Copyright, Publisher and Additional Information: © 2020 IEEE. Personal use of this material is permitted. Permission from IEEE must be obtained for all other users, including reprinting/ republishing this material for advertising or promotional purposes, creating new collective works for resale or redistribution to servers or lists, or reuse of any copyrighted components of this work in other works. Reproduced in accordance with the publisher's self-archiving policy.
Keywords: Airgap permeance; leakage flux; power factor; Vernier machine
Dates:
  • Accepted: 9 July 2020
  • Published (online): 1 December 2020
  • Published: 1 December 2020
Institution: The University of Sheffield
Academic Units: The University of Sheffield > Faculty of Engineering (Sheffield) > Department of Electronic and Electrical Engineering (Sheffield)
Funding Information:
FunderGrant number
Engineering and Physical Science Research CouncilEP/R004900/1
Depositing User: Symplectic Sheffield
Date Deposited: 16 Sep 2020 08:38
Last Modified: 04 Jan 2022 16:24
Status: Published
Publisher: IEEE
Refereed: Yes
Identification Number: https://doi.org/10.1109/ICEM49940.2020.9270829
Related URLs:

Export

Statistics